Garage Vacuum Installation Planning Worksheet
Choose two possible positions, measure their routes to the same cleaning job, then check each against the exact model's manual. Your result may be a useful set of questions rather than an installation decision.
Open printable worksheet1. Choose a Position
Park the vehicle normally. Label two survey positions A and B using repeatable wall references. Mark one exact cleaning endpoint E1 and use it for both routes. Record door, vehicle and storage positions. These are survey references, not drilling marks or recommended mounting heights.
Planning Record
Date / person: ____
Unit used throughout: ____
Exact model / variant, or Not selected: ____
Vehicle, door and storage positions: ____
Candidate A reference: ____
Candidate B reference: ____
Shared endpoint E1: ____
A visible wall, outlet or open area does not establish installation suitability.
2. Measure the Route
Record routes around obstacles, not a straight line through the car. Name turning points and measure each segment. Use one unit throughout. If a section is missing, mark the total incomplete.
Candidate A to E1
Position reference: ____
Obstacles and turning points: ____
Segment 1, start / end / length: ____
Segment 2, start / end / length: ____
Additional segments: ____
Total / unit / complete or incomplete: ____
Missing sections / next check: ____
Candidate B to the Same E1
Position reference: ____
Obstacles and turning points: ____
Segment 1, start / end / length: ____
Segment 2, start / end / length: ____
Additional segments: ____
Total / unit / complete or incomplete: ____
Missing sections / next check: ____
For another endpoint E2, copy both blocks. Date layout changes rather than mixing measurements from different conditions.
Filled Example: One Endpoint, Two Routes
Fictional measurements, not product specifications, recommended clearances or test results. The opening diagram is schematic, not a scaled drawing of these numbers.
- Unit and layout: metres; car parked, doors closed, storage unchanged. Model: not selected.
- E1: the same marked floor spot behind the parked car, shown below the car in the diagram.
- A: left-wall reference. Down the left-side route to turning point P1 = 3.0 m; P1 to E1 = 2.0 m. Total = 5.0 m, complete.
- B: right-wall reference. Down the right-side route to turning point Q1 = 2.5 m; Q1 to E1 = 2.0 m. Total = 4.5 m, complete.
- Observation: B's recorded route is 0.5 m shorter. Neither position is approved; exact-model instructions are still missing.
- Next action: obtain the correct manual and review both positions. Do not select B solely because its survey route is shorter.
A segment sum does not reproduce hose bends, connections, movement or usable reach, and does not establish cleaning performance.
3. Check the Manual
Use the exact model and variant. For each candidate, check mounting and fixings, footprint, doors and cabinets, electrical requirements, hose operation, and emptying/filter access. Write 'Not obtained' for missing instructions. Do not substitute another model's specifications, photographs or estimated clearances.
Manual Check: Copy for Each Candidate and Topic
Candidate / topic: ____
Observed fact or measurement: ____
Exact-model requirement, or Not obtained: ____
Manual title / revision / page / source URL: ____
Conflict or unanswered question: ____
Person responsible / evidence needed: ____
Next check / date: ____
Decide What to Investigate Next
Candidate to investigate: ____
Reason supported by the records: ____
Incomplete routes / unresolved conflicts: ____
Information needed / next action: ____
Owner / review date: ____
'Collect more information' is a valid outcome. This is an editorial planning template, not a manufacturer's manual or installation approval. It does not establish wall or electrical suitability, safe clearances, mounting methods or usable hose reach. Confirm current exact-model instructions and seek appropriately qualified advice where needed.